Transformer is the simplest device that is used to transfer electrical energy from one alternating-current circuit to another circuit or multiple circuits, through the process of electromagnetic induction. A transformer works on the principle of electromagnetic induction to step up or step down voltage. Transformer either increases AC voltage (Step-up transformer) or decreases AC voltage (Step-down transformer). Transformer which is normally utilized in the transmission and distribution of alternating current power is fundamentally a voltage control device. Transformer are used for a wide range of purposes, including increasing the voltage from electric generators to enable long-distance transmission of electricity and decreasing the voltage of conventional power circuits to run low-voltage devices like doorbells and toy electric trains.
A transformer is a static electrical device that transmits AC power from one circuit to another at a constant frequency, but the voltage level may be changed, implying the voltage can be increased or decreased depending on the requirement.
There are primarily two types of Transformer based on the operating voltage. The following are some of them:
Different types of Transformer are used in the power and electronics industries, depending on the core materials, which are:
Transformer come in a wide range of variants, each of which operates in a distinct field. Thus, based on their proposed use, transformer can be categorized as follows:
The fundamental principle of how the transformer functions are mutual induction between the two coils or Faraday’s Law of Electromagnetic Induction. Below is a description of how the transformer operates. The laminated silicon steel core of the transformer is covered by two distinct windings. According to the diagram below, the primary winding is the one to which the AC supply is connected, and the secondary winding is the one to which the load is connected. Only alternating current can be used because mutual induction between the two windings requires an alternating flux.
The transformer primary winding produces an alternating flux, known as the mutual flux, when an alternating voltage is applied, in accordance with the mutual inductance principle.
According to Faraday’s rule of electromagnetic induction, this alternating flux links the transformer primary and secondary windings magnetically and generates EMFs E1 in the primary winding and E2 in the secondary winding. The EMF (E1) is referred to as the primary EMF, while the EMF (E2) is the secondary EMF.
and
Dividing above equations, to obtain the ratio as:
From the expression above, it is clear that the size of EMFs E1 and E2 is dependent on the number of turns in the transformer primary and secondary windings, respectively. If N2 > N1, then E2 > E1, and the transformer will be a step-up transformer; if N2 < N1, then E2 < E1, and the transformer will be a step-down transformer.
If a load is now connected across the secondary winding, the load current I2 will flow through the load as a result of the EMF E2. As a result, a transformer makes it possible to transfer electricity with a change in voltage level from one electric circuit to another.
A transformer majorly consists of three parts:
The transformer core serves as a support for the winding. Additionally, it offers a magnetic flux flow channel with minimal resistance. As seen in the image, the winding is looped around the core. To cut down on losses in a transformer, it has a laminated soft iron core. Core composition is determined by variables including operational voltage, current, and power, among others. The core diameter is negatively correlated with iron losses and directly correlated with copper losses.
The copper wires that are wound over the transformer core are known as windings. Copper cables are used because Copper’s high conductivity reduces transformer loss because resistance to current flow lowers as conductivity rises. And copper’s high degree of ductility makes it possible to produce incredibly thin wires out of it.
The two basic types of windings are. windings for the primary and secondary coils. The primary winding is the group of winding turns that receive supply current. The number of winding turns from which output is derived is known as secondary winding. Insulation coating agents are used to insulate the primary and secondary windings from one another.
Transformer require insulation to keep the windings apart and prevent short circuits. This makes mutual induction easier. Transformer stability and durability are influenced by insulation agents. In a transformer, the following are employed as insulating mediums: Insulating fluid, tape, Paper, and Lamination made of wood.
A transformer main tank serves two purposes:
The majority of the huge transformer are submerged in oil. The transformer oil adds insulation between the conductors, improves heat dissipation from the coils, and has fault-detecting capabilities. Transformer oil is typically made of hydrocarbon mineral oil.
The oil conservator is situated above the transformer tank and bushings. Some transformer oil conservators contain a rubber bladder. When a transformer is loaded, the ambient temperature rises, causing the amount of oil inside the transformer to increase. The transformer conservator tank has enough room for the increased transformer oil. It also serves as a reservoir for oil that is used to insulate buildings.
All oil-immersed transformer with conservator tank includes it. It aids in the protection of the oil against moisture.
The majority of the power lost in the transformer is dissipated as heat. Radiators and fans aid in the dissipation of heat generated by the transformer and provide protection against failure. The majority of dry transformer are cooled by natural air.
An ideal transformer is a purely theoretical transformer that has no losses at all, including no core losses, copper losses, or other transformer losses. This transformer is thought to be 100% efficient.
The windings of the transformer are assumed to be entirely inductive, and the core of the transformer is assumed to be loss-free when creating the ideal transformer model. Additionally, the transformer has no leakage reactance (reactance is the opposition to the flow of current from the circuit element due to its inductance and capacitance). This indicates that the transformer primary and secondary windings are connected to the core of the transformer at 100% flux. However, every winding must have some inductive resistance that results in voltage drop and I2R loss. In a model of an ideal transformer, the windings are assumed to be perfect (totally inductive), which means that their resistance is zero.
Let Np is the main winding’s number of turns, whereas Ns is the secondary winding’s number of turns. When an AC voltage is given to the transformer main coil, the current generated creates an alternating magnetic flux that connects the secondary coil and generates an emf. The number of turns in the secondary coil determines the value of this emf. Consider an ideal (lossless) transformer with zero primary coil resistance (no voltage drop across coil) and all flux in the core connecting both primary and secondary windings. When the voltage Vp is delivered to the primary coil, let be the flux linkage in each turn in the core at time t owing to the current in the primary coil.
The induced emf or voltage (εs) in the secondary with Ns turns is then calculated.
εs = –Ns x dϕ/dt ……(1)
In addition, the alternating flux generates a reverse emf in the main. This is it.
εp = –Np x dϕ/dt ……(2)
And for an ideal transformer, εp=Vp
By approximation, if the secondary is an open circuit or the current drawn from it is modest, εs=Vs.
The voltage across the secondary coil is Vs. As a result, Equations (1) and (2) may be written as
Vs = –Ns x dϕ/dt ……(3)
Vp = –Np x dϕ/dt ……(4)
From Equations (3) and (4), we have
Vs / Vp = Ns / Np ……(5)
The above equation is known as Transformer Equation or Transformer Formula.
The following three assumptions are used to get the previous relationship:
Turn Ratio is a measure to determine whether the secondary coil of a transformer has more or lesser windings than the primary. The number of windings on a primary coil is equal to “Np,” while the number of windings on a secondary coil is “Ns,” representing the number of turns.
The power input and output will be equal if the transformer is perfect or 100 percent efficient (no energy losses).
ipVp = isVs ……(6)
Combining Equations (5) and (6), we have
ip/is = Vs/Vp= Ns/Np=K
The turn ratio, K, is defined in the preceding equation. If the secondary coil has more turns than the primary coil, this is the case (Ns>Np), and the voltage is stepped up (Vs>Vp). A step-up transformer is a name for this sort of setup. A step-down transformer is one in which the secondary coil has fewer turns than the primary coil (Ns<Np).
The efficiency of a transformer is also known as commercial efficiency. It is represented by the letter ‘η’. The efficiency of a Transformer is described as the ratio of output (in W or kW) to input (in W or kW).
Hence, the efficiency of transformer may be expressed as follows:
Efficiency (η) = (Power Output / Power Input)
The above equation can be used for an ideal transformer in which there are no transformer losses and all input energy is transferred to the output. As a result, the following equation is mostly used if transformer wastes are taken into account and the efficiency of the transformer is evaluated across the practical states.
Efficiency = ((Power O/P) / (Power O/P + Losses)) × 100%
or
Efficiency = (Power i/p – Losses) / Power i/p × 100 = 1− (Losses/ i/p Power) × 100
We used an ideal transformer in the previous equations (without any energy losses). However, some energy losses do occur in actual transformer for the following reasons:
The following are some of the most common uses for transformer:
Example 1: A transformer primary winding is powered by a 120 V ac source. If the turn ratio is 10, what does the secondary voltage equal?
Solution:
Given that, the turn ratio, N2/N1 = 10
And thevoltage across the primary coil, V1 = 120 V
Now, according to the transformer;’s equation:
V2/V1 = N2/N1
Substituting the given values,
V2/120 = 10
V2 = 1200 V
Example 2: A transformer has 1000 turns in the primary coil, and 8 A current flows through it. When the input power is 10 kW, and the output is 1000 V. Determine the number of turns in the secondary coil.
Solution:
Consider the case of an Ideal Transforemer,
Given that, Pin = Pout = 1000 W
But, Pout = VSIS
Now, the current through the secondary circuit is,
IS = Pout / VS =10000 / 1000 = 10 A
Therefore, the turns ratio of transformer is given by,
IP / IS = NS / NP
NS = (IP / IS) NP
= (8/10) × 1000
= 800 turns.
Example 3: The number of turns in the secondary coil of a 22 KVA, 2200V/220V single-phase transformer is 50, then find the number of primary turns. Neglect all kinds of losses in the transformer.
Answer:
The value of the turns ratio is
Vp/Vs = 2200/220
=10 = K
Number of primary turns
The value of the primary turns can be determined as:-
Np/Ns=K
Np/50=10
Np = 500
Example 4: Determine the primary current drawn in the transformer when the efficiency of the transformer provided is 75% and works on 100 V, 5 kVA and secondary voltage is 200 V.
Answer:
Given that, The kVA rating of transformer= 5 kVA
Primary voltage, V1 = 100 V
Secondary voltage, V2 = 200 V
Therefore, the Primary current I1 is given by,
I1= S / V1
= 5 kVA / 100
= 50 A
Question 1: What is Transformer?
Answer:
A transformer is an electrical device that transmits electrical energy from one circuit to another using electromagnetic induction and mutual induction. It’s most commonly utilised to increase (‘step up’) or decrease (‘step down’) voltage levels between circuits while keeping the AC frequency constant.
Question 2: List out some major types of Transformer.
Answer:
Transformer can be divided into many according to the purpose:
- Transformer types based on Voltage Level
- Step-down Transformer
- Step-up Transformer
- Transformer Types based on Core material
- Iron Core Transformer
- Ferrite Core Transformer
- Toroidal Core Transformer
- Air Core transformer
- Transformer Types based on Winding Arrangement
- Auto Winding Transformer
- Types of transformer based on Usage
- Power Transformer
- Small power transformer,
- Medium power transformer, and
- Large power transformer
- Measurement Transformer
- Distribution Transformer
- Pulse Transformer
- Audio Output Transformer
Question 3: What is the Turn Ratio?
Answer:
Turn Ratio is a measure to determine whether the secondary coil of a transformer has more or lesser windings than the primary. The number of windings on a primary coil is equal to “Np,” while the number of windings on a secondary coil is “Ns,” representing the number of turns.
Question 4: What is a step-up transformer?
Answer:
A step-up transformer secondary voltage is increased from the low primary voltage. The ratio of the primary to secondary winding in this type of transformer will be larger than one since the primary winding has fewer turns than the secondary winding.
Question 5: What is a step-down transformer?
Answer:
The secondary voltage of a step-up transformer is raised from the low primary voltage. Because the primary winding has fewer turns than the secondary winding in this sort of transformer, the ratio of the primary to secondary winding will be greater than one.